TM 11520238T3
878
Change 4
8277 SIGNAL NAME:
P1M4 MSL SKR POWER CONTROL (ACY) P1M4 SKR PWR OK (ACZ)
MEMORY LOCATION: 001271
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Controls application of seeker power.
REMARKS: From RHE to ECSP.
PASS:
If third digit on HOD is 1, 3, 5, or 7, go to paragraph 8278.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8278 SIGNAL NAME:
P1M4 MSL SKR POWER CONTROL (ACY) P1M4 SKR PWR OK (ACZ)
MEMORY LOCATION: 001705
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Controls application of seeker power.
REMARKS: From launcher through left outboard MRTU Type II to FCC.
PASS:
If third digit on HOD is 1, 3, 5, or 7, go to paragraph 8279.
FAIL: Location of fault: left outboard launcher, wiring from left outboard launcher to left outboard
MRTU Type II, left outboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8279 SIGNAL NAME:
P1M4 MSL SKR POWER
MEMORY LOCATION: 001410
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of seeker power (+28 VDC).
REMARKS: From ECSP to RHE.
PASS:
If third digit on HOD is 2, 3, 6, or 7, go to paragraph 8280.
FAIL: Location of fault: replace left outboard launcher (TM 91425475302).
8280 SIGNAL NAME:
P1M4 MSL SEEKER POWER (ACY) P1M4 SKR PWR OK (ACZ)
MEMORY LOCATION: 001666
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of seeker power (+28 VDC).
REMARKS: From launcher through left outboard MRTU Type II to FCC.
PASS:
If third digit on HOD is 2, 3, 6, or 7, go to paragraph 8283.
FAIL: Location of fault: left outboard launcher, wiring from left outboard launcher to left outboard
MRTU Type II, left outboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8281 SIGNAL NAME:
P1M4 CCM ACTIVATE CMD
MEMORY LOCATION: 001271
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands missile seeker to enter CCM mode.
REMARKS: From RHE to ECSP.
PASS:
If second digit on HOD is 4, 5, 6, or 7, go to paragraph 8282
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).