TM 11520238T3
898
8353 SIGNAL NAME:
P2M1 MSL TGT POLARITY CONTROL
MEMORY LOCATION: 001320
MEMORY DATA BIT(S):
1011
(BINARY)
CONDITION:
If the fourth digit is 0, 2, 4, or 6 and the third digit is 0, 1, 2, 3=BLACK
If the fourth digit is 0, 2, 4, or 6 and the third digit is 4, 5, 6, 7=AUTO
If the fourth digit is 1, 3, 5, or 7 and the third digit is 0, 1, 2, 3=WHITE
SIGNAL FUNCTION:
Directs missile seeker to track a black target on a white background, a white
target on a black background or automatic contrast.
REMARKS: From RHE to ECSP.
PASS:
If third digit on HOD corresponds to proper polarity, go to paragraph 8354.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8354 SIGNAL NAME:
P2M1 MSL TGT POLARITY CONTROL
MEMORY LOCATION: 001755
MEMORY DATA BIT(S):
1011
(BINARY)
CONDITION:
If the fourth digit is 0, 2, 4, or 6 and the third digit is 0, 1, 2, 3=BLACK
If the fourth digit is 0, 2, 4, or 6 and the third digit is 4, 5, 6, 7=AUTO
If the fourth digit is 1, 3, 5, or 7 and the third digit is 0, 1, 2, 3=WHITE
SIGNAL FUNCTION:
Directs missile seeker to track a black target on a white background, a white
target on a black background or automatic contrast.
REMARKS: From launcher through left inboard MRTU Type II to FCC.
PASS:
If third digit on HOD corresponds to proper polarity, refer to failure symptom index and next
failure symptom paragraph.
FAIL: Location of fault: left inboard launcher, wiring from left inboard launcher to left inboard MRTU
Type II, left inboard MRTU Type II. Troubleshoot wiring to isolate fault (TM 9142747520).
8355 SIGNAL NAME:
P2M1 MSL BIT CMD
MEMORY LOCATION: 001320
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Controls launcher BIT.
REMARKS: From RHE to ECSP.
PASS:
If third digit on HOD is 0, 1, 4, or 5, go to paragraph 8356.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8356 SIGNAL NAME:
P2M1 MSL BIT CMD
MEMORY LOCATION: 001755
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Controls launcher BIT.
REMARKS: From launcher through left inboard MRTU Type II to FCC.
PASS:
If third digit on HOD is 2, 3, 6, or 7, go to paragraph 8357.
FAIL: Location of fault: left inboard launcher, wiring from left inboard launcher to left inboard MRTU
Type II, left inboard MRTU Type II. Troubleshoot wiring to isolate fault (TM 9142747520).