TM 11520238T3
8136
8504 SIGNAL NAME:
P2M3 MSL RF CODE ACCEPT COMMAND
MEMORY LOCATION: 001757
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands missile seeker to accept RF code data from analog command lines
3 and 4. Commands ECSP to hook up analog commands 3 and 4 to selected
missile.
REMARKS: From launcher through left inboard MRTU Type II to FCC.
PASS:
If third digit on HOD is 1, 3, 5, or 7, go to paragraph 8505.
FAIL: Location of fault: left inboard launcher, wiring from left inboard launcher to left inboard MRTU
Type II, left inboard MRTU Type II. Troubleshoot wiring to isolate fault (TM 9142747520).
8505 SIGNAL NAME:
P2M3 MSL LASER CODE ACCEPT COMMAND
MEMORY LOCATION: 001322
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands laser code information received from RHE by launcher on coax A
and B to be relayed to identified missile.
REMARKS: From RHE to ECSP.
PASS:
If second digit on HOD is 4, 5, 6, or 7, go to paragraph 8506.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8506 SIGNAL NAME:
P2M3 MSL LASER CODE ACCEPT COMMAND
MEMORY LOCATION: 001757
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands laser code information received from RHE by launcher on coax A
and B to be relayed to identified missile.
REMARKS: From launcher through left inboard MRTU Type II to FCC.
PASS:
If second digit on HOD is 4, 5, 6, or 7, go to paragraph 81106.
FAIL: Location of fault: left inboard launcher, wiring from left inboard launcher to left inboard MRTU
Type II, left inboard MRTU Type II. Troubleshoot wiring to isolate fault (TM 9142747520).
8507 SIGNAL NAME:
P2M3 MSL COAX B CONNECT
MEMORY LOCATION: 001322
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands launcher to connect coax B to indicated missile.
REMARKS: From RHE to ECSP.
PASS:
If first digit on HOD is 4, 5, 6, or 7, go to paragraph 8508.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).