TM 1–1520–238–T–3Change 48–1738–647 SIGNAL NAME:P3M1 MSL COAX B CONNECTMEMORY LOCATION: 002026MEMORY DATA BIT(S):17(BINARY)CONDITION:(None)SIGNAL FUNCTION:Commands launcher to connect coax B to indicated missile.REMARKS: From launcher through right inboard MRTU Type II to FCC.PASS:If first digit on HOD is 4, 5, 6, or 7, go to paragraph 8–648.FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboardMRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).8–648 SIGNAL NAME:P3M1 MSL COAX A CONNECTMEMORY LOCATION: 001335MEMORY DATA BIT(S):18(BINARY)CONDITION:(None)SIGNAL FUNCTION:Commands launcher to connect coax A to indicated missile.REMARKS: From RHE to ECSP.PASS:If first digit on HOD is 2, 3, 6, or 7, go to paragraph 8–649.FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).8–649 SIGNAL NAME:P3M1 MSL COAX A CONNECTMEMORY LOCATION: 002026MEMORY DATA BIT(S):18(BINARY)CONDITION:(None)SIGNAL FUNCTION:Commands launcher to connect coax A to indicated missile.REMARKS: From launcher through right inboard MRTU Type II to FCC.PASS:If first digit on HOD is 2, 3, 6, or 7, go to paragraph 8–1106.FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboardMRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).8–650 SIGNAL NAME:4P3M1 MSL SKR LAUNCH PREPARE COMMAND (ACY) P3M1 SKR LNCH CMD (ACZ)MEMORY LOCATION: 001335MEMORY DATA BIT(S):19(BINARY)CONDITION:(None)SIGNAL FUNCTION:Prepares missile for free flight operation.REMARKS: From RHE to ECSP.PASS:If first digit on HOD is 0, 2, 4, or 6, go to paragraph 8–651.FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).8–651 SIGNAL NAME:P3M1 MSL SKR LAUNCH PREPARE COMMAND (ACY) P3M1 SKR LNCH CMD (ACZ)MEMORY LOCATION: 002026MEMORY DATA BIT(S):19(BINARY)CONDITION:(None)SIGNAL FUNCTION:Prepares missile for free flight operation.REMARKS: From launcher through right inboard MRTU Type II to FCC.PASS:If first digit on HOD is 0, 2, 4, or 6, go to paragraph 8–1126.FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboardMRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business