TM 11520238T3
Change 4
8189
8711 SIGNAL NAME:
P3M3 BIT PERFORMED
MEMORY LOCATION: 001350
MEMORY DATA BIT(S):
9
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates to FCC that BIT has been performed.
REMARKS: From RHE to FCC.
PASS:
If fourth digit on HOD is 2, 3, 6, or 7, go to paragraph 8712.
FAIL: Location of fault: replace RHE (TM 9142747520).
8712 SIGNAL NAME:
P3M3 BIT STATUS (ACY) P3M3 DISPLAY STATUS (ACZ)
MEMORY LOCATION: 001356
MEMORY DATA BIT(S):
1215
(HEX)
CONDITION:
If third digit displayed on HOD is 0 and second digit displayed
on HOD is 0=NO MSL
If third digit displayed on HOD is 0 or 4 and second digit displayed
on HOD is 2 or 3=SELECTED
If third digit displayed on HOD is 0 or 4 and second digit displayed
on HOD is 4 or 5=READY
If third digit displayed on HOD is 0 or 4 and second digit displayed
on HOD is 6 or 7=TRACKING
If third digit displayed on HOD is 3 or 7 and second digit displayed
on HOD is 0=CODED
If third digit displayed on HOD is 3 or 7 and second digit displayed
on HOD is 6=CAGED
If third digit displayed on HOD is 5 or 1 and second digit displayed
on HOD is 0=BIT NO GO
If third digit displayed on HOD is 5 or 1 and second digit displayed
on HOD is 2=FAILED
If third digit displayed on HOD is 5 or 1 and second digit displayed
on HOD is 6=BATTERY NO GO
If third digit displayed on HOD is 6 or 2 and second digit displayed
on HOD is 0=UNLATCHED
If third digit displayed on HOD is 6 or 2 and second digit displayed
on HOD is 2=MRTU NO GO
If third digit displayed on HOD is 6 or 2 and second digit displayed
on HOD is 4=RAIL NO GO
SIGNAL FUNCTION:
Provides missile status display for operator.
REMARKS: From RHE to FCC for display.
PASS:
If CONDITION corresponds to selected message, go to failure symptom index and next failure
symptom paragraph.
FAIL: Location of fault: RHE, wiring from RHE to right inboard launcher, right inboard launcher.
Troubleshoot wiring to isolate fault (TM 9142747520).
8713 SIGNAL NAME:
P3M3 UNLATCH INDICATE
MEMORY LOCATION: 001426
MEMORY DATA BIT(S):
16
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates to RHE missile is unlatched.
REMARKS: From launcher to RHE.
PASS:
If second digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 8714.
FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to RHE, RHE.
Troubleshoot wiring to isolate fault (TM 9142747520).