TM 11520238T3
8206
Change 4
8777 SIGNAL NAME:
P3M4 TYPE (ACY) P3M4 MSL TYPE (ACZ)
MEMORY LOCATION: 001422
MEMORY DATA BIT(S):
78
(BINARY)
CONDITION:
If fifth digit displayed on HOD is 0, and fourth digit displayed on HOD is 0, 1, 2, or
3=TRAINING
If fifth digit displayed on HOD is 1, and fourth digit displayed on HOD is 0, 1, 2, or
3=TACTICAL
If fifth digit displayed on HOD is 1, and fourth digit displayed on HOD is 4, 5, 6, or
7=NONE
SIGNAL FUNCTION:
Indicates a tactical, training or no missile at location.
REMARKS: From ECSP to RHE.
PASS:
If CONDITION corresponds to installed type of missiles, go to paragraph 8778.
FAIL: Location of fault: right inboard launcher (TM 91425475302).
8778 SIGNAL NAME:
P3M4 TYPE (ACY) P3M4 MSL TYPE (ACZ)
MEMORY LOCATION: 002000
MEMORY DATA BIT(S):
78
(BINARY)
CONDITION:
If fourth digit displayed on HOD is 0, 1, 2, or 3=TRAINING
If fifth digit displayed on HOD 1, 3, 5, or 7=TACTICAL
If fifth digit displayed on HOD 1, 3, 5, or 7 and fourth digit displayed on HOD is 0, 1, 2,
or 3=NONE
SIGNAL FUNCTION:
Indicates a tactical, training or no missile at location.
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
If CONDITION corresponds to installed type of missiles, refer to failure symptom index and
next failure symptom paragraph.
FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboard
MRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8779 SIGNAL NAME:
P3M4 MSL DEICE #1 CMD
MEMORY LOCATION: 001326
MEMORY DATA BIT(S):
5
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Sends command to launcher ECSP to arm deicing squib.
REMARKS: From RHE to ECSP.
PASS:
If fifth digit on HOD is 4, 5, 6, or 7, go to paragraph 8780.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8780 SIGNAL NAME:
P3M4 MSL DEICE #1 CMD
MEMORY LOCATION: 002017
MEMORY DATA BIT(S):
5
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Sends command to launcher ECSP to arm deicing squib.
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
If fifth digit on HOD is 4, 5, 6, or 7, go to paragraph 8811.
FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboard
MRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).