TM 11520238T3
8218
Change 4
8824 SIGNAL NAME:
P3M4 MSL COAX B CONNECT
MEMORY LOCATION: 002023
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands launcher to connect coax B to indicated missile.
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
If first digit on HOD is 4, 5, 6, or 7, go to paragraph 8825.
FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboard
MRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8825 SIGNAL NAME:
P3M4 MSL COAX A CONNECT
MEMORY LOCATION: 001332
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands launcher to connect coax A to indicated missile.
REMARKS: From RHE to ECSP.
PASS:
If first digit on HOD is 2, 3, 6, or 7, go to paragraph 8826.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8826 SIGNAL NAME:
P3M4 MSL COAX A CONNECT
MEMORY LOCATION: 002023
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands launcher to connect coax A to indicated missile.
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
If first digit on HOD is 2, 3, 6, or 7, go to paragraph 81106.
FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboard
MRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
8827 SIGNAL NAME:
P3M4 MSL SKR LAUNCH PREPARE COMMAND (ACY)
P3M4 SKR LNCH CMD (ACZ)
MEMORY LOCATION: 001332
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Prepares missile for free flight operation.
REMARKS: From RHE to ECSP.
PASS:
If first digit on HOD is 0, 2, 4, or 6, go to paragraph 8828.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
8828 SIGNAL NAME:
P3M4 MSL SKR LAUNCH PREPARE COMMAND (ACY)
P3M4 SKR LNCH CMD (ACZ)
MEMORY LOCATION: 002023
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Prepares missile for free flight operation.
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
If first digit on HOD is 0, 2, 4, or 6, go to paragraph 81126.
FAIL: Location of fault: right inboard launcher, wiring from right inboard launcher to right inboard
MRTU Type II, right inboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).