TM 1–1520–238–T–3Change 48–2418–912 SIGNAL NAME:P4M2 UNLATCH INDICATEMEMORY LOCATION: 002051MEMORY DATA BIT(S):17(BINARY)CONDITION:(None)SIGNAL FUNCTION:Indicates to operator when a missile is unlatched.REMARKS: From launcher through right outboard MRTU Type II to FCC for display.PASS:If first digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 8–913.FAIL: Location of fault: right outboard launcher, wiring from right outboard launcher to right outboardMRTU Type II, right outboard MRTU Type II. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).8–913 SIGNAL NAME:P4M2 UNLATCH INDICATEMEMORY LOCATION: 002074MEMORY DATA BIT(S):17(BINARY)CONDITION:(None)SIGNAL FUNCTION:Indicates to operator when a missile is unlatched.REMARKS: From FCC through right outboard MRTU Type II to launcher.PASS:If first digit displayed on HOD is 0, 1, 2, or 3, refer to failure symptom index and next failuresymptom paragraph.FAIL: Location of fault: right outboard MRTU Type II, wiring from right outboard MRTU Type II to FCC,FCC. Troubleshoot wiring to isolate fault (TM 9–1230–476–20–2).8–914 SIGNAL NAME:P4M2 UPPER LOWER DISPLAY STATUS (ACY) P4M2 PRIORITY IND (ACZ)MEMORY LOCATION: 001357MEMORY DATA BIT(S):8(BINARY)CONDITION:If the second digit displayed on HOD is 0, 2, 4, or 6=UPPERIf the second digit displayed on HOD is 1, 3, 5, or 7=LOWERSIGNAL FUNCTION:Indicates to operator when a selected missile has been assigned to upper orlower channel.REMARKS: From RHE to FCC for display.PASS:If CONDITION corresponds to selected channel, go to paragraph 8–915.FAIL: Location of fault: replace RHE (TM 9–1427–475–20).8–915 SIGNAL NAME:P4M2 TYPE STATUS DISPLAY (ACY) P4M2 TYPE (ACZ)MEMORY LOCATION: 001357MEMORY DATA BIT(S):9–11(OCTAL)CONDITION:If the first digit displayed on HOD is 0=NONEIf the first digit displayed on HOD is 1=TACTICAL LASERIf the first digit displayed on HOD is 4=UNIDENTIFIEDIf the first digit displayed on HOD is 5=TRAINING LASERSIGNAL FUNCTION:Provides type of missile data for display to operator.REMARKS: From RHE to FCC for display.PASS:If CONDITION corresponds to installed type of missiles, go to paragraph 8–916.FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault(TM 9–1427–475–20).
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business