TM 1–1520–238–T–3
8–267
8–1014 SIGNAL NAME:
P4M3 MSL INDIRECT FIRE LO
MEMORY LOCATION: 002071
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands low flight profile for LOAL operation.
REMARKS: From launcher through right outboard MRTU Type II to FCC.
PASS:
If fourth digit on HOD is 1, 3, 5, or 7, go to paragraph 8–1108.
FAIL: Location of fault: right outboard launcher, wiring from right outboard launcher to right outboard
MRTU Type II, right outboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9–1427–475–20).
8–1015 SIGNAL NAME:
P4M3 MSL INDIRECT FIRE HI
MEMORY LOCATION: 001307
MEMORY DATA BIT(S):
11
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands high flight profile for LOAL operation.
REMARKS: From RHE to ECSP.
PASS:
If third digit on HOD is 4, 5, 6, or 7, go to paragraph 8–1016.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9–1427–475–20).
8–1016 SIGNAL NAME:
P4M3 MSL INDIRECT FIRE HI
MEMORY LOCATION: 002071
MEMORY DATA BIT(S):
11
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands high flight profile for LOAL operation.
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
If third digit on HOD is 4, 5, 6, or 7, go to paragraph 8–1108.
FAIL: Location of fault: right outboard launcher, wiring from right outboard launcher to right outboard
MRTU Type II, right outboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9–1427–475–20).
8–1017 SIGNAL NAME:
P4M3 MSL RF CODE ACCEPT COMMAND
MEMORY LOCATION: 001307
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands missile seeker to accept RF code data from analog command lines
3 and 4. Commands ECSP to hook up analog commands 3 and 4 to selected
missile.
REMARKS: From RHE to ECSP.
PASS:
If third digit on HOD is 1, 3, 5, or 7, go to paragraph 8–1018.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9–1427–475–20).