TM 11520238T3
8282
81073 SIGNAL NAME:
P4M4 MSL INDIRECT FIRE LO
MEMORY LOCATION: 002070
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands low flight profile for LOAL operation.
REMARKS: From launcher through right outboard MRTU Type II to FCC.
PASS:
If fourth digit on HOD is 1, 3, 5, or 7, go to paragraph 81108.
FAIL: Location of fault: right outboard launcher, wiring from right outboard launcher to right outboard
MRTU Type II, right outboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
81074 SIGNAL NAME:
P4M4 MSL INDIRECT FIRE HI
MEMORY LOCATION: 001306
MEMORY DATA BIT(S):
11
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands high flight profile for LOAL operation.
REMARKS: From RHE to ECSP.
PASS:
If third digit on HOD is 4, 5, 6, or 7, go to paragraph 81075.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).
81075 SIGNAL NAME:
P4M4 MSL INDIRECT FIRE HI
MEMORY LOCATION: 002070
MEMORY DATA BIT(S):
11
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands high flight profile for LOAL operation.
REMARKS: From launcher through right inboard MRTU Type II to FCC.
PASS:
If third digit on HOD is 4, 5, 6, or 7, go to paragraph 81108.
FAIL: Location of fault: right outboard launcher, wiring from right outboard launcher to right outboard
MRTU Type II, right outboard MRTU Type II. Troubleshoot wiring to isolate fault
(TM 9142747520).
81076 SIGNAL NAME:
P4M4 MSL RF CODE ACCEPT COMMAND
MEMORY LOCATION: 001306
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Commands missile seeker to accept RF code data from analog command lines
3 and 4. Commands ECSP to hook up analog commands 3 and 4 to selected
missile.
REMARKS: From RHE to ECSP.
PASS:
If third digit on HOD is 1, 3, 5, or 7, go to paragraph 81077.
FAIL: Location of fault: RHE, wiring from RHE to ECSP, ECSP. Troubleshoot wiring to isolate fault
(TM 9142747520).