TM 11520238T3
Change 4
115
1110 SIGNAL NAME:
PYLON POS (ACY) PYLON POS AID (ACZ)
MEMORY LOCATION: 001465
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
Monitor HOD while using the PYLON ACTG SW; memory location response should
increase when up (flight stow) is selected and decrease, then go negative when down
(ground stow) is selected.
SIGNAL FUNCTION:
Indicates pylon position to RHE.
REMARKS: From FCC to RHE. Pylon elevation positioning data.
PASS:
If CONDITION has been met, go to paragraph 1111.
FAIL: Location of fault: wiring from external stores elevation controller to pylon actuator controller.
Troubleshoot wiring to isolate fault (TM 9142747520).
1111 SIGNAL NAME:
PYLN 1 POS (ACY) P1 POSITION (ACZ)
MEMORY LOCATION: 001655
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
Monitor HOD while using the PYLON ACTG SW; memory location response should
increase when up (flight stow) is selected and decrease, then go negative when down
(ground stow) is selected.
SIGNAL FUNCTION:
Indicates pylon 1 position.
REMARKS: From pylon actuator controller (PAC) 1 through LH outboard (OUTBD) MRTU Type II to
FCC. Pylon 1 elevation positioning data.
PASS:
If CONDITION has been met, go to paragraph 1112.
FAIL: Location of fault: external stores elevation controller, wiring from external stores controller to
pylon actuator controller 1, pylon actuator controller 1, wiring from pylon actuator controller 1 to
LH OUTBD MRTU Type II, LH OUTBD MRTU Type II. Troubleshoot wiring to isolate fault
(TM 91090208232).
1112 SIGNAL NAME:
PAC 1 STAT
MEMORY LOCATION: 001654
MEMORY DATA BIT(S):
419
(SCALAR)
CONDITION:
(None)
SIGNAL FUNCTION:
Generates PYLN ACTUATOR CONTROLLER NOGO LT OUTBD FD/LS
message.
REMARKS: From PAC through LH OUTBD MRTU Type II to FCC.
PASS:
If sixth digit on HOD is 0, go to paragraph 1113.
FAIL: Location of fault: pylon actuator controller 1, pylon actuator controller 1, wiring from pylon
actuator controller 1 to LH OUTBD MRTU Type II, LH OUTBD MRTU Type II. Troubleshoot
wiring to isolate fault (TM 91090208232).
1113 SIGNAL NAME:
PYLN 1 STAT (ACY) P1 COM STAT (ACZ)
MEMORY LOCATION: 001434
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Generates PYLON NO GO FD/LS message.
REMARKS: From FCC to RHE. Pylon 1 status to RHE.
PASS:
If first digit on HOD is 0, 2, 4, or 6, go to paragraph 1127.
FAIL: Location of fault: replace RHE (TM 9142747520).