FAILURE SYMPTOM INDEX (cont)
Symptom
Refer to paragraph
INCORRECT NUMBER OF ROCKETS REMAINING IN EACH ZONE OF P4
1247
CANNOT SELECT ROCKET TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1249
CANNOT EMERGENCY JETTISON EXTERNAL STORES . . . . . . . . . . . . . . . .
1254
Personnel Required:
(2)
References:
TM 11270476T
TM 15855265T
TM 91090208232
TM 91230476202
TM 9127022123
TM 9142747520
TM 111520238232
Equipment Conditions:
Ref
Condition
TM 91090208232
AERIAL ROCKET
CONTROL SYSTEM
MAINTENANCE
OPERATIONAL CHECK in
progress
NOTE
All multiplex read code responses are read from right to
left.
Multiplex read codes must be used in conjunction with
applicable Maintenance Operational Check (MOC) in
progress.
Multiplex read codes are observed on the HOD (ADC) or
CDU (ADD).
MULTIPLEX READ CODE INTERPRETATIONS
121 SIGNAL NAME:
PLT SAFE/ARM SW
MEMORY LOCATION: 001120
MEMORY DATA BIT(S):
1213
(BINARY)
CONDITION:
If the third digit displayed on HOD is 0 or 4=OFF
If the third digit displayed on HOD is 2 or 6=SAFE
If the third digit displayed on HOD is 3 or 7=ARM
SIGNAL FUNCTION:
Selects weapon system status.
REMARKS: From pilot fire control panel (FCP) through lefthand (LH) forward avionics bay (FAB)
multiplex remote terminal unit (MRTU) Type I to fire control computer (FCC).
PASS:
If third digit displayed on heads out display (HOD) corresponds to the setting of pilot FCP
SAFE/OFF/ARM switch, go to paragraph 122.
FAIL: Location of fault: pilot FCP, wiring from pilot FCP to LH FAB MRTU Type I, LH FAB MRTU Type