TM 11520238T3
Change 4
1217
1250 SIGNAL NAME:
RKT TYPE FOR EACH ZONE (ACY) RKT ZONE TYPE (ACZ)
MEMORY LOCATION: 001162
MEMORY DATA BIT(S):
811
(HEX )
CONDITION:
If the third digit displayed on HOD is 0, 1, 2, or 3=HPD40
If the third digit displayed on HOD is 4, 5, 6, or 7=HRC40
If the fourth digit displayed on HOD is 1 and the third digit
is 0, 1, 2, or 3=HDP40
If the fourth digit displayed on HOD is 1 and the third digit
is 4, 5, 6, or 7=WP40
If the fourth digit displayed on HOD is 2 and the third digit
is 0, 1, 2, or 3=ILM40
If the fourth digit displayed on HOD is 2 and the third digit
is 4, 5, 6, or 7=SMK40
If the fourth digit displayed on HOD is 3 and the third digit
is 0, 1, 2, or 3=HDP66
If the fourth digit displayed on HOD is 3 and the third digit
is 4, 5, 6, or 7=HRC66
If the fourth digit displayed on HOD is 4 and the third digit
is 0, 1, 2, or 3=ILM66
If the fourth digit displayed on HOD is 4 and the third digit
is 0, 1, 2, or 3=SMK66
If the fourth digit displayed on HOD is 5 and the third digit
is 4, 5, 6, or 7=MPS66
If the fourth digit displayed on HOD is 5 and the third digit
is 0, 1, 2, or 3=NONE
SIGNAL FUNCTION:
Strobed signal displays on HOD the type of rockets remaining in each zone.
REMARKS: From RCP through LH FAB MRTU Type I to FCC.
PASS:
If CONDITION corresponds to rocket type, go to paragraph 1251.
FAIL: Location of fault: LH FAB MRTU Type I, wiring from LH FAB MRTU Type I to RCP, RCP.
Troubleshoot wiring to isolate fault (TM 91090208232).
1251 SIGNAL NAME:
PENETRATION SETTING (ACY) RCP FUSE SELECT (ACZ)
MEMORY LOCATION: 001161
MEMORY DATA BIT(S):
811
(HEX)
CONDITION:
If the third digit displayed on HOD is 0, 1, 2, or 3=SPQ
If the third digit displayed on HOD is 4, 5, 6, or 7=10M
If the fourth digit displayed on HOD is 1 and the third digit
is 0, 1, 2, or 3=15M
If the fourth digit displayed on HOD is 1 and the third digit
is 4, 5, 6, or 7=20M
If the fourth digit displayed on HOD is 2 and the third digit
is 0, 1, 2, or 3=25M
If the fourth digit displayed on HOD is 2 and the third digit
is 4, 5, 6, or 7=30M
If the fourth digit displayed on HOD is 3 and the third digit
is 0, 1, 2, or 3=35M
If the fourth digit displayed on HOD is 3 and the third digit
is 4, 5, 6, or 7=40M
If the fourth digit displayed on HOD is 4 and the third digit
is 0, 1, 2, or 3=45M
If the fourth digit displayed on HOD is 4 and the third digit
is 4, 5, 6, or 7=BUNKER
SIGNAL FUNCTION:
Reports selected rocket penetration setting to FCC.
REMARKS: From RCP through LH FAB MRTU Type I to FCC.
PASS:
If CONDITION agrees with selected setting, go to paragraph 1252 (ACY) or 1251A (ACZ).
FAIL: Location of fault: RCP, wiring from RCP to LH FAB MRTU Type I, LH FAB MRTU Type I.
Troubleshoot wiring to isolate fault (TM 91090208232).