TM 11520238T3
148
1422 SIGNAL NAME:
SYM GEN STATUS WORD PROCESSOR FAIL
MEMORY LOCATION: 000774
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
FAIL indicates a failed state of processor card A11.
REMARKS: From symbol generator to 1553 bus.
PASS:
If first digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 1423.
FAIL: Location of fault: replace symbol generator (TM 111520238232).
1423 SIGNAL NAME:
SYM GEN STATUS WORD AUTO STBY
MEMORY LOCATION: 000774
MEMORY DATA BIT(S):
16
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
STBY indicates symbol generator has gone into standby due to no valid
message for 0.5 seconds.
REMARKS: From symbol generator to 1553 bus.
PASS:
If second digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 1424.
FAIL: Location of fault: replace FCC (TM 91230476201).
1424 SIGNAL NAME:
SYM GEN STATUS WORD RAM FAIL
MEMORY LOCATION: 000774
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates RAM status on A2, A3, and A4 cards.
REMARKS: From symbol generator to 1553 bus.
PASS:
If fifth digit displayed on HOD is 0, 1, 4, or 5, go to paragraph 1425.
FAIL: Location of fault: replace symbol generator (TM 111520238232).
1425 SIGNAL NAME:
SYM GEN STATUS WORD RAM FAIL
MEMORY LOCATION: 000774
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates RAM status on A12 card.
REMARKS: From symbol generator to 1553 bus.
PASS:
If second digit displayed on HOD is 0, 1, 2, or 3, go to paragraph 1426.
FAIL: Location of fault: replace symbol generator (TM 111520238232).
1426 SIGNAL NAME:
SYM GEN STATUS WORD INTERNAL SYNC
MEMORY LOCATION: 000774
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates either TADS or PNVS FLIR is not present.
REMARKS: From symbol generator to 1553 bus.
PASS:
If third digit displayed on HOD is 0, 1, 4, or 5, go to paragraph 1427.
FAIL: Location of fault: replace symbol generator (TM 111520238232).