TM 11520238T3
Change 5
153
TABLE 151.
ASCII CODE CONVERSIONS
(BITS 611 OR BITS 1419)
00 =
@
0B =
K
16 =
V
21 =
!
2C =
,
37 =
7
01 =
A
0C =
L
17 =
W
22 =
2D =
38 =
8
02 =
B
0D =
M
18 =
X
23 =
#
2E =
.
39 =
9
03 =
C
0E =
N
19 =
Y
24 =
$
2F =
/
3A =
:
04 =
D
0F =
O
1A =
Z
25 =
%
30 =
0
3B =
;
05 =
E
10 =
P
1B =
[
26 =
&
31 =
1
3C =
<
06 =
F
11 =
Q
1C =
\
27 =
32 =
2
3D =
=
07 =
G
12 =
R
1D =
]
28 =
(
33 =
3
3E =
>
08 =
H
13 =
S
1E =
^
29 =
)
34 =
4
3F =
?
09 =
I
14 =
T
1F =
_
2A =
*
35 =
5
0A =
J
15 =
U
20 =
2B =
+
36 =
6
Personnel Required:
(2)
References:
TM 1127047620
TM 11270476T
TM 11520238T7
TM 11520238T8
TM 91230476201
TM 91230476202
Equipment Conditions:
Ref
Condition
TM 11270476T
TADS MAINTENANCE
OPERATIONAL CHECK in
progress
NOTE
All multiplex read code responses are read from right to
left.
Multiplex read codes must be used in conjunction with
applicable Maintenance Operational Check (MOC) in
progress.
Multiplex read codes are observed on the HOD (ADC) or
CDU (ADD).
MULTIPLEX READ CODE INTERPRETATIONS
151 SIGNAL NAME:
PLT GND OVRD SW
MEMORY LOCATION: 001555
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates PLT/GND OVRD switch position.
REMARKS: From copilot/gunner (CPG) fire control panel (FCP) through lefthand (LH) forward
avionics bay (FAB) multiplex remote terminal unit (MRTU) Type I to fire control computer
(FCC).
PASS:
If third digit on heads out display (HOD) is 1, 3, 5, or 7, go to paragraph 152.
FAIL: Location of fault: CPG FCP, wiring from CPG FCP to LH FAB MRTU Type I, LH FAB MRTU
Type I. Troubleshoot wiring to isolate fault (TM 91230476202).