TM 11520238T3
163
163 SIGNAL NAME:
ORT RKT TRIG
MEMORY LOCATION: 000414
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Initiates rocket firing sequence.
REMARKS: From CPG FCP through CPG MRTU Type III to FCC.
PASS:
If second digit on HOD is 4, 5, 6, or 7, go to paragraph 1633.
FAIL: Location of fault: go to Chapter 12, paragraph 1216.
164 SIGNAL NAME:
CPG MSL ACTION
MEMORY LOCATION: 000415
MEMORY DATA BIT(S):
4
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates CPG missile action.
REMARKS: From CPG FCP through CPG MRTU Type III to FCC.
PASS:
If sixth digit on HOD is 1, go to paragraph 1640.
FAIL: Location of fault: CPG cyclic, wiring from CPG cyclic to CPG FCP, CPG FCP, wiring from CPG
FCP to CPG MRTU Type III, CPG MRTU Type III. Troubleshoot wiring to isolate fault
(TM 9142747520).
165 SIGNAL NAME:
PLT MSL ACTION
MEMORY LOCATION: 000415
MEMORY DATA BIT(S):
5
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates pilot missile action.
REMARKS: From CPG FCP through CPG MRTU Type III to FCC.
PASS:
If fifth digit on HOD is 4, 5, 6, or 7, go to paragraph 166.
FAIL: Location of fault: pilot cyclic, wiring from CPG cyclic to CPG FCP, CPG FCP, wiring from CPG
FCP to CPG MRTU Type III, CPG MRTU Type III. Troubleshoot wiring to isolate fault
(TM 9142747520).
166 SIGNAL NAME:
MSL TRIG 1ST DETENT
MEMORY LOCATION: 000415
MEMORY DATA BIT(S):
6
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates missile firing sequence.
REMARKS: From CPG FCP through CPG MRTU Type III to FCC.
PASS:
If fifth digit on HOD is 2, 3, 6, or 7, go to paragraph 167.
FAIL: Location of fault: CPG FCP, wiring from CPG FCP to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 91230476202).
167 SIGNAL NAME:
MSL TRIG 2ND DETENT
MEMORY LOCATION: 000415
MEMORY DATA BIT(S):
7
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates missile firing sequence.
REMARKS: From CPG FCP through CPG MRTU Type III to FCC.
PASS:
If fifth digit on HOD is 1, 3, 5, or 7, go to Chapter 8, paragraph 81179.
FAIL: Location of fault: CPG FCP, wiring from CPG FCP to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 91230476202).