TM 11520238T3
Change 5
191
CHAPTER 19
GENERATOR MULTIPLEX READ CODES
FAILURE SYMPTOM INDEX
Symptom
Refer to paragraph
GEN 1 INDICATOR IS LIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
GEN 2 INDICATOR IS LIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
Personnel Required:
(2)
References:
TM 11520238T6
Equipment Conditions:
Ref
Condition
TM 11520238T6
AC ELECTRICAL POWER
GENERATION
MAINTENANCE
OPERATIONAL CHECK in
progress
NOTE
All multiplex read code responses are read from right to
left.
Multiplex read codes must be used in conjunction with
applicable Maintenance Operational Check (MOC) in
progress.
Multiplex read codes are observed on the HOD (ADC) or
CDU (ADD).
MULTIPLEX READ CODE INTERPRETATIONS
191 SIGNAL NAME:
GEN 1 STATUS
MEMORY LOCATION: 001532
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
Valid only during generator test.
SIGNAL FUNCTION:
Monitors field excitation.
REMARKS: From generator 1 through power distribution box to righthand (RH) forward avionics bay
(FAB) multiplex remote terminal unit (MRTU) Type I.
PASS:
If second digit displayed on heads out display (HOD) is 4, 5, 6, or 7, go to paragraph 192.
FAIL: Location of fault: generator 1, wiring from generator to RH FAB MRTU Type I, RH FAB MRTU
Type I. Troubleshoot wiring to isolate fault (TM 11520238T6).