TM 11520238T3
276
Change 5
2727 SIGNAL NAME:
INS PBIT STATUS
MEMORY LOCATION: 002737
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates INS periodic bit GO or NOGO.
REMARKS: From EGI to FCC.
PASS:
If fourth digit displayed on CDU is 5, go to paragraph 2728.
FAIL: Location of fault: Replace EGI (TM 111520238231).
2728 SIGNAL NAME:
INS IBIT IN PROGRESS
MEMORY LOCATION: 11
(BINARY)
MEMORY DATA BIT(S):
002737
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates INS initiated BIT in progress.
REMARKS: From EGI to FCC.
PASS:
If third digit displayed on CDU is 0 or 2, go to paragraph 2729.
FAIL: Location of fault: Replace EGI (TM 111520238231).
2729 SIGNAL NAME:
INS IBIT STATUS
MEMORY LOCATION: 12
(BINARY)
MEMORY DATA BIT(S):
002737
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates INS initiated BIT GO or NOGO.
REMARKS: From EGI to FCC.
PASS:
If third digit displayed on CDU is 2, go to paragraph 2730.
FAIL: Location of fault: Replace EGI (TM 111520238231).
2730 SIGNAL NAME:
EGR PBIT STATUS
MEMORY LOCATION: 002700
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates EGR periodic bit GO or NOGO.
REMARKS: From EGI to FCC.
PASS:
If second digit displayed on CDU is 2, 3, 6 or 7, go to paragraph 2731.
FAIL: Location of fault: Replace EGI (TM 111520238231).
2731 SIGNAL NAME:
EGR IBIT STATUS
MEMORY LOCATION: 002700
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates EGR initiated bit GO or NOGO.
REMARKS: From EGI to FCC.
PASS:
If first digit displayed on CDU is 4, 5 or 6, go to paragraph 2732.
FAIL: Location of fault: Replace EGI (TM 111520238231).
2732 SIGNAL NAME:
EGR FAILED
MEMORY LOCATION: 002737
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates EGR has failed.
REMARKS: From EGI to FCC.
PASS:
If first digit displayed on CDU is 0 or 4, go to paragraph 2733.
FAIL: Location of fault: Replace EGI (TM 111520238231).