TM 1-1520-238-T-44–1014–20.ENG START CIRCUIT BREAKER – DOES NOT STAY CLOSED (WITH ENG START NO 1 4–20SWITCH IN START POSITION) (cont)19. Check for short between P439–A16 and ground.Does short exist?YESGo to step 20.NOGo to step 21.20. Detach P977. Check for short betweenP439–A16 and ground.Does short exist?YESRepair shorted wire betweenP439–A16 and P977–A13.Go to paragraph 4–12.NOReplace start mode relay panel(TM 1-1520-238-23).21. Identify and detach wires from (A402): TB2–8–A,TB2–8–B, TB2–8–E, TB2–8–F, TB2–8–J, andTB2–8–N. Check for short between (A402):J21–A2 and ground,J21–A11 and ground,J21–A14 and ground,J21–A15 and ground,J21–A16 and ground,J15–A2 and ground.Does short exist?YESRepair shorted wire between(A402):J21–A2 and TB2–8–N,J21–A11 and TB2–8–F,J21–A14 and TB2–8–A,J21–A15 and TB2–8–B,J21–A16 and TB2–8–E,J15–A2 and TB2–8–J.Go to paragraph 4–12.NORefer to paragraph 6–12 totroubleshoot drive system.END OF TASK