TM 1-1520-238-T-4
6116
649.
HOD XMN 1 READING DISPLAYS 28 LB OR LESS OIL PRESSURE (cont)
649
5. Detach P673. Check for short between:
J5791 and J5793,
J5792 and J5793.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 613.
NO
Go to step 6.
6. Check for short between:
P5791and P5793,
P5792 and P5793.
Does short exist?
YES
Replace oil system 1 heat
exchanger pressure transducer
(TM 1-1520-238-23).
NO
Refer to TM 9-1230-476-20-2 to
troubleshoot multiplex
subsystem.
END OF TASK