TM 1-1520-238-T-4
6132.2
Change 1
660.1. HOD NGB 1 READING DISPLAYS 140 C OR HIGHER OIL TEMPERATURE (cont)
660.1
7. Check for open between:
J61F and P439A10,
P439A14 and P463c.
(A402):
J21A10 and J21A14.
Does open exist?
YES
Repair open wire.
Go to paragraph 613.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc emergency bus
pilot station)
8. Check for short between P61H and P61J.
Does short exist?
YES
Replace NGB 2 oil temperature
probe (TM 1-1520-238-23).
NO
Repair shorted wire between:
J61H and P403 B1,
J61J and P403 B2,
J403B1 and P67387,
J403B2 and P67386.
Go to paragraph 613.
END OF TASK