TM 1-1520-238-T-4
6138
664.
HOD XMN 1 READING DISPLAYS 140 C OR HIGHER OIL TEMPERATURE (cont)
664
6. Check for open between:
P75510 and P68287,
P75511 and P68286.
Does open exist?
YES
Repair open wire.
Go to paragraph 613.
NO
Go to step 7.
7. Check for short between:
P75510 and ground,
P75511 and ground,
P68286 and ground,
P68287 and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 613.
NO
Replace main transmission oil
system 1 temperature
transducer (TM 1-1520-238-23).
END OF TASK