HOD XMN 2 READING DISPLAYS 140 C OR HIGHER OIL TEMPERATURE (cont)
668
6. Check for open between J7557 and J7558.
Does open exist?
YES
Replace main transmission oil
system 2 temperature probe
(TM 1-1520-238-23).
NO
Go to step 7.
7. Check for short between P7557 and J7558.
Does short exist?
YES
Replace main transmission oil
system 2 temperature probe
(TM 1-1520-238-23).
NO
Repair shorted wire between:
P7557 and P68285,
P7558 and P68284.
Go to paragraph 613.