TM 1-1520-238-T-4
6160
Change 5
679.
TEMP TR INDICATOR LIGHTS (cont)
679
6. Remove TGB thermistor probe RT7
(TM 1-1520-238-23). Check for short between
P201A and ground.
Does short exist?
YES
Repair shorted wire between
P201A and thermistor RT7.
Reinstall thermistor
(TM 1-1520-238-23).
NO
Replace TGB thermistor probe
(TM 1-1520-238-23).
7. Check resistance between P201S and
P201C.
Is resistance greater than 1 megohm?
YES
Go to step 9.
NO
Go to step 8.
8. Remove TGB thermistor probe RT8 RH
(TM 1-1520-238-23). Check for short between
P201C and ground.
Does short exist?
YES
Repair shorted wire between
P201C and thermistor RT8.
Reinstall thermistor
(TM 1-1520-238-23).
NO
Replace TGB thermistor probe
(TM 1-1520-238-23).
9. Check resistance between P201S and P201K.
Is resistance greater than 1 megohm?
YES
Go to step 11.
NO
Go to step 10.
10. Remove TGB thermistor probe
(TM 1-1520-238-23). Check for short between
P201K and ground.
Does short exist?
YES
Repair shorted wire between
P201K and thermistor RT10.
Reinstall thermistor
(TM 1-1520-238-23).
NO
Replace TGB thermistor probe
(TM 1-1520-238-23).
11. Check resistance between P201S and P201E.
Is resistance greater than 1 megohm?
YES
Replace TGB temperature alarm
(TM 1-1520-238-23).
NO
Go to step 12.
12. Remove TGB thermistor probe
(TM 1-1520-238-23). Check for short between
P201E and ground.
Does short exist?
YES
Repair shorted wire between
P201E and thermistor RT9.
Reinstall thermistor
(TM 1-1520-238-23).
NO
Replace TGB thermistor probe
(TM 1-1520-238-23).
END OF TASK