TM 1-1520-238-T-5
8140
869.
CPG SDD DOES NOT INDICATE ENGINE 1 AND/OR ENGINE 2 OIL PRESSURE
869
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
LN1 door opened
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 0.1 to 1 VDC at P7522 and P7523.
Is voltage present?
YES
Replace CPG SDD panel
(TM 1-1520-238-23).
NO
Go to step 2.
2. Check for open between:
P701 and P7522,
P702 and P7523.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace pilot ENG OIL indicator
(TM 1-1520-238-23).
END OF TASK