TM 1-1520-238-T-5
8156
884.
CPG ENGRTR RPM% INDICATOR DOES NOT INDICATE NR
884
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Nontransparent
barrier removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach wire ends at (A326):
TB19H and TB19J.
Check for short between:
P734 and P735,
P736 and P734,
P736 and P735.
Does short exist?
YES
Repair shorted wire between:
P734 and P467B10,
P735 and P467B11.
(A326):
J5B10 and TB19H,
J5B11 and TB19J.
Go to paragraph 810.
NO
Go to step 2.
2. Check for open between:
P734 and (A326)TB19H,
P735 and (A326)TB19J.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace CPG ENGRTR
RPM% indicator
(TM 1-1520-238-23).
END OF TASK