TM 1-1520-238-T-5
8162
890.
CPG SDD PANEL DOES NOT INDICATE ENGINE 1 AND/OR ENGINE 2 TGT
890
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach P75. Check for short between:
P681 and P682,
P681 and ground,
P682 and ground.
Does short exist?
YES
Repair shorted wire between:
P681 and P7528,
P682 and P7529.
Go to paragraph 810.
NO
Go to step 2.
2. Check for open between:
P681 and P7528,
P682 and P7529.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace CPG SDD panel
(TM 1-1520-238-23).
END OF TASK