TM 1-1520-238-T-5
8193
8107. PILOT CLOCK EDGELIGHTING DOES NOT LIGHT
8107
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot center circuit breaker panel, close LT
PRI circuit breaker. Check for 5 VDC between
(A326):
J9A15 and J9A16.
Is voltage present?
YES
Go to step 3.
NO
Go to step 2.
2. Check for 5 VDC at
(A326)TB133D.
Is voltage present?
YES
Repair open wire between
(A326):
J9A15 and TB133D,
J9A16 and TB134D.
Go to paragraph 8105.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot edgelights.
3. Check for 5 VDC between
P1211 and P1213.
Is voltage present?
YES
Replace pilot clock
(TM 1-1520-238-23).
NO
Repair open wire between:
P487A15 and P1213,
P487A16 and P1211.
Go to paragraph 8105.
END OF TASK