TM 1-1520-238-T-6
910
92.
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS (cont)
92
GCU 1
M69-044-2
GENERATOR CONTACTOR
(TYPICAL)
(TYPICAL)
GCU
ELECTRICAL POWER DISTRIBUTION BOX (INTERNAL VIEW)
GENERATOR
CONTACTOR K1
GCU 2
D
GENERATOR
CONTACTOR K2
-
Figure 91.
AC Electrical Power Generation System Major Components Location (Sheet 2 of 2)
d. DC Electrical Power Generation System.
The dc electrical power generation system (fig. 92) consists
of T/R 1 and 2, and a dc bus tie contactor.
(1) T/R.
T/R 1 is mounted in the forward left side of the main transmission bay. T/R 2 is mounted in the
forward right side of the main transmission bay. Each T/R is a solid state LRU containing one electrical connector
and two terminal studs for power and control connections.