TM 1-1520-238-T-6
961
92.
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS (cont)
92
s. CPG station dc ground circuit protection.
NOTE
Refer to CPG station (fig. 951) for configuration and component locations.
1.
CPG CIRCUIT BREAKER PANEL 1
M69263
1
Figure 951.
CPG Station
Table 925 contains a listing of the circuit breakers associated with the CPG station dc ground circuit protection,
along with each circuit breakers rating in amps.
Table 925.
CPG Station DC Ground Circuit Protection
CPG Circuit Breaker Panel 1 (fig. 952)
CB NO.
CB NAME
RATING
CB19
MSL R OUTBD LCHR DC
0.5 amp
CB22
MSL R INBD LCHR DC
0.5 amp
CB23
MSL L INBD LCHR DC
0.5 amp
CB25
MSL L OUTBD LCHR DC
0.5 amp
CB27
MSL ARM
0.5 amp