TM 1-1520-238-T-6
970
93.
EQUIPMENT DATA
93
AC Electrical Power Generation System Produces:
2000 amperes for 0.050 seconds
1400 amperes for one second
1000 amperes for six seconds
Battery
Power rating . . . . . . . . . . . . . . . . . . . . . .
33 amperes for 12 minutes
Navigation Lights
Power requirement . . . . . . . . . . . . . . . .
28 VDC
Formation Lights
Power requirement . . . . . . . . . . . . . . . .
115 VAC, single phase
Anti-Collision Lights
Power requirement . . . . . . . . . . . . . . . .
115 VAC
Power supply output . . . . . . . . . . . . . . .
400 VDC anode voltage
200 VDC trigger voltage
Squat Switch
Power requirement . . . . . . . . . . . . . . . .
28 VDC
94.
EQUIPMENT CONFIGURATION
94
Not applicable.
95.
SAFETY, CARE AND HANDLING OF EQUIPMENT
95
Not applicable.
96.
CONTROLS AND INDICATORS
96
The electrical system is controlled by switches in the pilot station (fig. 969) and provides fault signals to the
caution/warning/advisory system in both the pilot station and the CPG station (fig. 970). Table 91 provides a
listing of the controls, switches and indicators pertaining to the electrical system along with a description of their
function.