TM 1-1520-238-T-6
9150
912.
AC ELECTRICAL POWER GENERATION MAINTENANCE OPERATIONAL CHECK
912
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-1
TM 1-1520-238-T-3
TM 1-1520-238-T-4
TM 1-1520-238-T-8
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
Paragraph 945
EXTERNAL POWER
POWER UP completed
Paragraph 910
AC ELECTRICAL POWER
GENERATION POWER
UP completed
NOTE
Refer to pilot station (fig. 997) for configuration and component
locations.
If referenced out of one paragraph or volume into another for additional
troubleshooting, upon completion of the task, return to the maintenance
operational check for the original paragraph or volume.
1. Perform GEN FD/LS (TM 1-1520-238-T-1).
NOTE
If a discrepancy is noted during the FD/LS check, perform the corrective
action indicated in TM 1-1520-238-T-1. If the discrepancy still exists after
performing the corrective action required, continue performing the
maintenance operational check.
If GENERATOR 1 NOGO LH XMSN BAY appears
on heads up display (HOD) and no fault is found, then
replace generator 1 (TM 1-1520-238-23).
If GENERATOR 1 CONTROL NOGO PLT ELEC
PWR CNTR appears on HOD and no fault is found,
then replace generator 1 control (TM 1-1520-238-23).
If GENERATOR 2 NOGO RH XMSN BAY appears
on HOD and no fault is found, then replace generator
2 (TM 1-1520-238-23).