TM 1-1520-238-T-6
9194
936.
POWER IS NOT AVAILABLE TO ALL DC EMERGENCY BUS CIRCUIT BREAKERS
936
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Electrical power
distribution cover removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
Detach wire (A402):
TB1-1-B and TB1-1-C. Check for open between
wire ends of (A402):
TB1-1-C and J29-2,
TB1-1-C and J29-3,
TB1-1-B and J29-1.
Does open exist?
YES
Repair open wire.
Go to paragraph 923.
NO
Repair open between (A402):
TB1-1-B and J32-G.
Go to paragraph 923.
END OF TASK