TM 1-1520-238-T-6
9228
Change 8
952.
115 VAC IS NOT PRESENT FROM AC ELEC UTIL PWR CIRCUIT BREAKER (CB6)
952
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-7
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door opened
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With power applied, and on ground service utility
receptacle circuit breaker panel, check that AC
ELEC UTIL PWR circuit breaker (CB6) is
closed.
Does AC ELEC UTIL PWR circuit breaker
(CB6) stay closed?
YES
Go to step 3.
NO
Go to step 2.
2. Open AC ELEC UTIL PWR circuit breaker
(CB6). Check for short between:
J16-B and ground,
J16-F and ground,
J16-E and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 947.
NO
Replace AC ELEC UTIL PWR
circuit breaker
(TM 1-1520-238-23).
3. Check for open between:
CB6-A2 and J16-E,
CB6-B2 and J16-F,
CB6-C2 and J16-B.
Does open exist?
YES
Repair open wire.
Go to paragraph 947.
NO
Go to step 4.
4. With AC ELEC UTIL PWR circuit breaker (CB6)
closed, check for continuity (less than 1 ohm)
between:
CB6-A1 and CB6-A2,
CB6-B1 and CB6-B2,
CB6-C1 and CB6-C2.
Does continuity exist?
YES
Go to step 5.
NO
Replace AC ELEC UTIL PWR
circuit breaker
(TM 1-1520-238-23).
5. Check for open between:
(A402)XK1-A1 and CB6-A1,
(A402)XK1-B1 and CB6-B1,
(A402)XK1-C1 and CB6-C1.
Does open exist?
YES
Repair open wire.
Go to paragraph 947.
NO
Go to paragraph 912 to
troubleshoot ac electrical power
generation.
END OF TASK