TM 1-1520-238-T-6
9241
962.
FORMATION LIGHTS MAINTENANCE OPERATIONAL CHECK (cont)
962
1. Perform the maintenance operational check as follows:
Task
Result
a. On pilot center circuit breaker panel
(fig. 9125), check that LT FORM circuit
breaker (CB90) is closed.
If LT FORM circuit breaker (CB90) does not stay
closed, go to paragraph 964.
M69-111
LT FORM
Figure 9125.
Pilot Center Circuit Breaker Panel
b. On pilot EXT LT/INTR LT panel (fig. 9126),
set FORM control to BRT. Check that all
formation lights function.
If left, right, tail, and fuselage formation lights do not
light, go to paragraph 965.
If left, formation light does not light, go to paragraph
966.
If right formation light does not light, go to paragraph
967.
If tail formation light does not light, go to paragraph
968.
If fuselage formation light does not light, go to
paragraph 969.
M69-112
FORM
CONTROL