TM 1-1520-238-T-6
9348
9132. CPG EDGE-LIGHTS MAINTENANCE OPERATIONAL CHECK (cont)
9132
1. Perform the maintenance operational check as follows:
Task
Result
a. On CPG circuit breaker panel 1 (fig. 9152),
check that the PRI LT circuit breaker (CB14)
is closed.
If PRI LT circuit breaker (CB14) does not stay closed,
go to paragraph 9134.
M69185
PRI LT
Figure 9152.
CPG Circuit Breaker Panel 1
b. On CPG INTR LT panel (fig. 9153), place L
CSL, R CSL, and INST to BRT.
If CPG edge-lights are not lighted, go to
paragraph 9135.
L CSL CONTROL
M69186
INST CONTROL
R CSL CONTROL
Figure 9153.
CPG INTR LT Panel
c. On CPG INTR LT panel (fig. 9153), check
that all edge-lights controlled by L CSL are
lighted (fig. 9154).
If all CPG left console edge-lights do not light, go to
paragraph 9136.
d. On CPG INTR LT panel, check that all
edge-lights controlled by R CSL are lighted.
If all CPG right console edge-lights do not light, go to
paragraph 9137.
e. On CPG INTR LT panel, check that all
edge-lights controlled by INST are lighted.
If all CPG instrument panel edge-lights do not light, go
to paragraph 9138.
f. Check that CPG INTR LT panel edge-light is
lighted (fig. 9153).
If CPG INTR LT edge-light panel dos not light, go to
paragraph 9139.
g. Check that all channel 1 No. 1 indicators are
lighted (fig. 9155).
If all channel 1 No. 1 indicators do not light, go to
paragraph 9140.
h. Check that all channel 1 No. 2 indicators are
lighted.
If all channel 1 No. 2 indicators do not light, go to
paragraph 9141.