9186. LASER CIRCUIT BREAKER (CB4) DOES NOT STAY CLOSED OR 115 VAC
9186
IS NOT PRESENT AT (A97): J1-A, J1-B, J1-D
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
TM 1-1270-476-T
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, set BATT/EXT PWR
switch to EXT PWR.
Does LASER circuit breaker (CB4) stay
closed?
YES
Go to step 4.
NO
Go to step 2.
2. Open CB4. Set BATT/EXT PWR switch to OFF.
Check for short between (A97):
J1-D and ground,
J1-B and ground,
J1-A and ground.
Does short exist?
YES
Go to step 3.
NO
Refer to TM 1-1270-476-T to
troubleshoot TADS.
3. Detach wire at CB4-A2, CB4-B2, CB4-C2.
Check for short between (A97):
J1-A and ground,
J1-B and ground,
J1-D and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 9172.
NO
Replace LASER circuit breaker
(CB4) (TM 1-1520-238-23).
4. Set BATT/EXT PWR switch to OFF. Check for
short between:
CB4-A1 and (A97)J2-A,
CB4-B1 and (A97)J2-B,
CB4-C1 and (A97)J2-C,
CB4-A2 and (A97)J1-D,
CB4-B2 and (A97)J1-B,
CB4-C2 and (A97)J1-A.
Does open exist?
YES
Repair open wire.
Go to paragraph 9172.
NO
Replace LASER circuit breaker
(CB4) (TM 1-1520-238-23).
END OF TASK