TM 1-1520-238-T-6
9522
9246. STAB AUTO DC CIRCUIT BREAKER (CB3) DOES NOT STAY CLOSED OR 28 VDC IS
9246
NOT PRESENT AT P2-f
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 1-1520-238-T-7
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, place BATT/EXT
PWR switch to EXT PWR.
Does STAB AUTO DC circuit breaker (CB3)
stay closed?
YES
Go to step 4.
NO
Go to step 2.
2. Open CB3. Set BATT/EXT PWR switch to OFF.
Check for short between P2-f and ground.
Does short exist?
YES
Go to step 3.
NO
Refer to TM 1-1520-238-T-7 to
troubleshoot stabilator.
3. Detach wire at CB3-2. Check for short between
P2-f and ground.
Does short exist?
YES
Repair shorted wire between
CB3-2 and P2-f.
Go to paragraph 9233.
NO
Replace STAB AUTO DC circuit
breaker (CB3)
(TM 1-1520-238-23).
4. Set BATT/EXT PWR switch to OFF. Check for
open between:
CB3-1 and CB85-1
CB3-2 and P2-f.
Does open exist?
YES
Repair open wire.
Go to paragraph 9233.
NO
Replace STAB AUTO DC circuit
breaker (CB3)
(TM 1-1520-238-23).
END OF TASK