TM 1-1520-238-T-6
9528
9249. CIRCUIT PROTECTION SYSTEM (DC ESSENTIAL BUS 3 CPG STATION)
9249
MAINTENANCE OPERATIONAL CHECK (cont)
Task
Result
d. On CPG circuit breaker panel 2 (fig. 9188),
check that CDU (CB6) circuit breaker stays
closed.
If CDU circuit breaker (CB6) does not stay closed, go
to paragraph 9261.
e. On pilot ELEC PWR panel (fig. 9186), set
BATT/EXT PWR switch to OFF.
f. Remove to gain access, CPG circuit breaker
panel 1 (TM 1-1520-238-23).
g. On pilot ELEC PWR panel (fig. 9186), set
BATT/EXT PWR switch to EXT PWR.
h. Check for 28 VDC at P769-A and P769-J.
If 28 VDC is not present, go to paragraph 9262.
i. On pilot ELEC PWR panel, set BATT/EXT
PWR switch to OFF.
j. Check for continuity between (A77):
J4-J and J2-32.
If continuity does not exist, go to paragraph 9251.
k. Check for continuity between (A77):
J4-J and J2-24,
J4-J and J2-33.
If continuity does not exist, go to paragraph 9252.
l. Check for continuity between (A77):
J4-J and J2-20,
J4-J and J2-21.
If continuity does not exist, go to paragraph 9253.
m. Check for continuity between (A77):
J4-A and J2-7.
If continuity does not exist, go to paragraph 9254.
n. Check for continuity between (A77):
J4-A and J2-11.
If continuity does not exist, go to paragraph 9255.
o. Check for continuity between (A77):
J4-A and J2-9.
If continuity does not exist, go to paragraph 9256.
p. Check for continuity between (A77):
J4-A and J2-8.
If continuity does not exist, go to paragraph 9257.
q. Check for continuity between (A77):
J4-A and J2-10.
If continuity does not exist, go to paragraph 9258.
r. Check for continuity between (A77):
J4-A and J2-14.
If continuity does not exist, go to paragraph 9260.
s. Check for continuity between (A77):
J4-A and J2-13.