TM 1-1520-238-T-69–5639–270. JETT CIRCUIT BREAKER (CB34) – DOES NOT STAY CLOSED 9–270OR 28 VDC IS NOT PRESENT AT (A76): J1-P AND J1-RTools:NomenclaturePartNumberTool Kit, ElectricalSC518099CLA06Repairer’sMultimeter, DigitalAN/PSM-45Personnel Required:68XArmament/Electrical Systems RepairerOne person to assistReferences:TM 1-1520-238-23TM 1-1520-238-T-8WARNINGTurn off power before detaching orattaching wires and connectors. Highcurrent 28 VDC or 115 VAC is present.Failure to do so could result in death orserious injury.1. On pilot ELEC PWR panel, set BATT/EXT PWRswitch to EXT PWR.Does JETT circuit breaker (CB34) stayclosed?YESGo to step 4.NOGo to step 2.2. On pilot center circuit breaker panel, open JETTcircuit breaker (CB34). Set BATT/EXT PWRswitch to OFF. Check for short between (A76):J1-P and ground,J1-R and ground.Does short exist?YESGo to step 3.NORefer to TM 1-1520-238-T-8 totroubleshoot external storesjettison.3. Detach wire at CB34-2. Check for short between(A76):J1-P and ground,J1-R and ground.Does short exist?YESRepair shorted wire.Go to paragraph 9–263.NOReplace JETT circuit breaker(CB34) (TM 1-1520-238-23).4. Set BATT/EXT PWR switch to OFF. Check foropen between:CB34-2 and (A76)J1-P,CB34-2 and (A76)J1-R.Does open exist?YESRepair open wire.Go to paragraph 9–263.NOReplace JETT circuit breaker(CB34) (TM 1-1520-238-23).END OF TASK
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business