TM 1-1520-238-T-69–5809–287. RDR ALT CIRCUIT BREAKER (CB31) – DOES NOT STAY CLOSED 9–287OR 28 VDC IS NOT PRESENT AT (A76): J1-f AND J1-gTools:NomenclaturePartNumberTool Kit, ElectricalSC518099CLA06Repairer’sMultimeter, DigitalAN/PSM-45Personnel Required:68XArmament/Electrical Systems RepairerOne person to assistReferences:TM 1-1520-238-23TM 11-1520-238-23-2WARNINGTurn off power before detaching orattaching wires and connectors. Highcurrent 28 VDC or 115 VAC is present.Failure to do so could result in death orserious injury.1. On pilot ELEC PWR panel, set BATT/EXT PWRswitch to EXT PWR.Does RDR ALT circuit breaker (CB31) stayclosed?YESGo to step 4.NOGo to step 2.2. On pilot center circuit breaker panel, open RDRALTcircuit breaker (CB31). Set BATT/EXT PWRswitch to OFF. Check for short between (A76):J1-f and ground,J1-g and ground.Does short exist?YESGo to step 3.NORefer to TM 11-1520-238-23-2to troubleshoot radar altimeterset.3. Detach wire at CB31-2. Check for short between(A76):J1-f and ground,J1-g and ground.Does short exist?YESRepair shorted wire.Go to paragraph 9–263.NOReplace RDR ALT circuitbreaker (CB31)(TM 1-1520-238-23).4. Set BATT/EXT PWR switch to OFF. Check foropen between:CB31-2 and (A76)J1-f,CB31-2 and (A76)J1-g.Does open exist?YESRepair open wire.Go to paragraph 9–263.NOReplace RDR ALT circuitbreaker (CB31)(TM 1-1520-238-23).END OF TASK