TM 1-1520-238-T-69–6349–331. PILOT AND CPG CAUTION/WARNING PANELS – INDICATORS 9–331FUNCTIONAL DATATools:NomenclaturePartNumberTool Kit, ElectricalSC518099CLA06Repairer’sMultimeter, DigitalAN/PSM-45Personnel Required:68XArmament/Electrical Systems RepairerOne person to assistReferences:TM 1-1520-238-23Equipment Conditions:RefConditionTM 1-1520-238-23Helicopter safedWARNINGTurn off power before detaching or attaching wires and connectors. Highcurrent 28 VDC or 115 VAC is present. Failure to do so could result in deathor serious injury.NOTERefer to pilot station (fig. 9–208) and CPG station (fig. 9–209) for cockpitconfiguration and equipment.1. PILOT CAUTION / WARNING PANEL1M69-284Figure 9–208.Pilot Station1. CPG CAUTION / WARNING PANEL1M69-285Figure 9–209.CPG station