TM 1-1520-238-T-6
9726
9382. ENG 2 FIRE PULL INDICATOR IS NOT LIGHTED WITH PRESS TO TEST INDICATOR
9382
PRESSED
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Press and hold PRESS TO TEST indicator,
check for 28 VDC at J1039-A5.
Is voltage present?
YES
Replace ENG 2 FIRE PULL
indicator (TM 1-1520-238-23).
NO
Go to step 2.
2. Check for open between:
P747-e and J1039-A5,
P747-d and J1039-A4.
Does open exist?
YES
Repair open wire.
Go to paragraph 9364.
NO
Replace multi-channel dimming
controller (TM 1-1520-238-23).
END OF TASK