TM 1-1520-238-T-6
9774
9411.
SQUAT SWITCH SYSTEM MAINTENANCE OPERATIONAL CHECK
9411
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Fixture, Squat Switch
7-3621MF002
Make item
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 1-1520-238-T-4
TM 1-1520-238-T-8
TM 9-1090-208-23-2
TM 9-1230-476-20-2
TM 11-1520-238-23-2
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Battery installed
Paragraph 945
EXTERNAL POWER
POWER UP completed
Paragraph 910
AC ELECTRICAL POWER
GENERATION POWER
UP completed
WARNING
Turn off power before detaching or attaching wires and connectors. High
current 28 VDC or 115 VAC is present. Failure to do so could result in death
or serious injury.
M69-415
4
5
6
1.
PILOT ELEC PWR PANEL
2.
PILOT FIRE CONTROL PANEL
3.
PILOT ARM / SAFE INDICATOR
4.
PILOT AFT CIRCUIT BREAKER PANEL
5.
PILOT CENTER CIRCUIT BREAKER PANEL
6.
PILOT FORWARD CIRCUIT BREAKER PANEL
3
2
1
Figure 9246.
Pilot Station