TM 1-1520-238-T-7
1082
1011. FUEL SYSTEM POWER DOWN
1011
Tools:
Nomenclature
Part Number
Tool Kit, Aircraft
SC518099CLA01
Mechanics
Personnel Required:
67R
Attack Helicopter Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
Paragraph 1010
FUEL SYSTEM POWER
UP completed
1. At CPG station, set switches/circuit breakers (fig. 1031 thru 1033 and 1039) as follows:
Location
Name
Position (set to)
Circuit breaker panel 1
PRI LT
EMERG BATT ICS
EMERG BATT ENG INST
Open
Open
Open
INTR LT panel
INST
L CSL
OFF
OFF
FUEL panel
ORIDE
TK SEL
BOOST
TRANS
PLT
NORM
OFF
OFF
Selectable digital display
SELECT
OFF
2. On pilot center circuit breaker panel (fig. 1034), open the following circuit breakers:
ENG INST
FUEL APU
LT CAUT
FIRE DETR ENG 2
ENG LVR
FIRE DETR ENG 1
FIRE DETR APU
THROT
FUEL BST
FIRE EXTGH CPG
RTR BRK
FUEL TRANS
FIRE EXTGH APU
COMM ICS
FUEL XFEED
FUEL VLV ACTR
FIRE EXTGH PLT
LT PRI
FUEL FILL
EMERG HYD
3. At pilot station, set switches as follows (fig. 1035 thru 1037):
Location
Name
Position (set to)
FUEL panel
TRANS
CROSSFEED
ENG 2
BOOST
EXT TK
ENG 1
OFF
NORM
OFF
OFF
OFF
OFF
EXT LT/INTR LT panel
INST
L CSL
OFF
OFF
Dim/test panel
DGT OFF/NORM/TST
DIM
OFF
OFF