TM 1-1520-238-T-7Change 510–9510–17. FUEL CROSSFEED/BOOST SYSTEM – MAINTENANCE OPERATIONAL CHECK (cont)10–17M70-066TK SELSWITCHBOOSTSWITCHORIDESWITCHFigure 10–48.CPG FUEL PanelTaskResulte. On pilot power quadrant (fig. 10–49), moveengineNO 1 and NO 2PWRlevers toLOCKOUT.M70-062PWRLEVERSRTR BKSWITCHFigure 10–49.Pilot Power QuadrantTaskResultf. On pilot center circuit breaker panel(fig. 10–50), check that FUEL BST andIf FUEL BST circuit breaker does not stay closed, goto paragraph 10–21.FUEL XFEEDcircuit breakers are closed.(ADA)If FUEL XFEEDcircuit breaker does not stayclosed, go to paragraph 10–22.(ADB)If FUEL XFEEDcircuit breaker does not stayclosed, go to paragraph 10–35B.g. (ADB) On pilot and CPG caution/warningpanels (fig. 10–51), check that greenXFEEDindicators are not lighted.If pilot and CPG green XFEED indicators are lighted,go to paragraph 10–35I.