TM 1-1520-238-T-710–11110–21. FUEL BST CIRCUIT BREAKER – DOES NOT STAY CLOSED10–21Tools:NomenclaturePartNumberTool Kit, ElectricalSC518099CLA06Repairer’sMultimeter, DigitalAN/PSM-45Personnel Required:68XArmament/Electrical Systems RepairerOne person to assistReferences:TM 1-1520-238-T-6TM 1-1520-238-23Equipment Conditions:RefConditionTM 1-1520-238-23Electrical powerdistribution box coverremovedWARNINGTurn off power before detaching orattaching wires and connectors. Highcurrent 28 VDC or 115 VAC is present.Failure to do so could result in death orserious injury.1. Detach P1 from (A402)J1. Check that FUELBST circuit breaker is closed.Does circuit breaker stay closed?YESGo to step 2.NORefer to TM 1-1520-238-T-6 totroubleshoot circuit protectionsystem (dc essential bus 2 –pilot station).2. Detach wire end at (A402)TB2-29-P. Check forshort between P191-B1 and ground.Does short exist?YESRepair shorted wire. Go to paragraph 10–17.NOGo to step 3.3. Attach P191. Check for short between detachedwire end at (A402)TB2-29-P and ground.Does short exist?YESReplace CPG FUEL panel(TM 1-1520-238-23).NOGo to paragraph 10–17.END OF TASK