TM 1-1520-238-T-7
10130.16
Change 5
1035I.
PILOT AND CPG GREEN XFEED INDICATORS ARE LIGHTED WITH ENGINE 1
1035I
AND ENGINE 2 CROSSFEED VALVES AT NORMAL (ADB)
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Electrical power
distribution box cover
removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for short between (A402)J16A1 and
ground.
Does short exist?
YES
Go to step 2.
NO
Repair shorted wire between
P440A1 and P18125.
Go to paragraph 1017.
2. Detach wire at (A402)XK56A1. Check for
short between (A402)J16A1 and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 1017.
NO
Replace relay (A402)K56
(TM 1-1520-238-23).
END OF TASK