TM 1-1520-238-T-7
10160.4
Change 5
1048A.
FUEL QUANTITY SYSTEM CAPACITANCE AND INDICATING TEST
1048A
(USING PSD 60-1AF TEST SET) (cont)
Task
Result
b. Attach test set ground cable to test set
chassis jack.
c. Attach test set ground cable to helicopter
ground.
d. Ensure that test set (fig. 1070.5) ON/OFF
switch is set to ON.
LOZCOMP
.
HIZGND
COMP
TU
10-1000 PF
10-1000 PF
SIMULATOR
PSD60-1AF
PF
MW
COMPGND
LOZGND
SHLDGND
HIZSHLD
COMPSHLD
LOZSHLD
COMPHIZ
LOZHIZ
COMP
TU
MEASURE INT
SIM TU & COMP
SIM TU ONLY
AIRCRAFT ONLY
PF
MW
MEASURE EXT
INDICATOR
TANK
UNITS
LOZ
HIZ
COMP
SHLD
T
U
COMP
ON
OFF
CHASSIS
EXTENDED
RANGE
TWO TERMINAL
MEASUREMENT
CHASSIS
GROUND
JACK
ON / OF
SWITCH
LCD
INDICATOR
FUNCT
SWITCH
SELECT
SWITCH
TU
SIMULATOR
DECADE
TU
SIMULATOR
VERNIER
TANK
UNITS
HIZ
TANK
UNITS
LOZ
INDICATOR
HIZ
INDICATOR
LOZ
M70-363
Figure 1070.5.
Capacitance Resistance Bridge Test Set