1056. FUEL LOW AFT INDICATORS ARE NOT LIGHTED WITH PILOT FUEL QUANTITY
1056
INDICATOR AFT VERTICAL DISPLAY INDICATING BETWEEN 22 AND 26
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L40 door removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for open between:
(A402)J31B1 and P40121,
(A402)J31B2 and P40122.
Does open exist?
YES
Repair open wire. Go to
paragraph 1047.
NO
Go to step 2.
2. Check for open between (A82) 1J224 and
ground.
Does open exist?
YES
Go to step 3.
NO
Replace SDC
(TM 1-1520-238-23).
3. With P18 detached, check FUEL LOW AFT
indicator.
Is indicator lighted?
YES
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot
caution/warning system.
NO
Go to step 4.
4. Check for short between:
P40124 and ground,
P1822 and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 1047.
NO
Go to step 5.
5. Check for open between:
P2648 and P444B1,
P2649 and P444B2.
Does open exist?
YES
Repair open wire.
Go to paragraph 1047.
NO
Adjust aft fuel quantity low level
sensor
(TM 1-1520-238-23).
END OF TASK